- Main circuit breakder: Imported ABB VD4 vacuum circuit breaker or VS1,VT2,ZN12,vacuum circuit breaker. 主配断路器:本开关柜可配用VS1、VT2、ZN12真空断路器,也可配用进口ABB公司生产的VD4真空断路器。
- Parameter collection interface circuit of vacuum circuit breaker is a vital important electrical interface. 摘要真空断路器的参数采集接口电路是为主系统需要采集机械信号参量的重要的电接口。
- Permanent Magnetic Actuator (PMA) is a new type of actuator for Vacuum Circuit Breaker (VCB). 永磁操动机构一种新型的真空断路器操动机构,该机构具有可靠性高、零部件少、免维护等优点。
- Analysis the cause of producing operating overvoltage of vacuum circuit breaker, a method of restricting operating overvoltage. 分析了真空断路器的操作过电压产生原因,探讨了限制操作过电压的方法。
- Abstract Vacuum circuit breaker(VCB) has been widely used in electric power system, especially, it takes most market share of 12 kV power system. 摘要 真空断路器在电力系统的使用已经相当普遍,特别是在12kV电压等级占有绝对优势。
- Vacuum circuit breaker with permanent magnetic actuator adopt two steady state two coil configuration, which is developed by many big companies include ABB. 摘要ABB等诸多大公司研制的永磁机构真空断路器,大多采用双稳态双线圈结构。
- This article introduces how to realize the mechanical interlock of integral vacuum circuit breaker with the disconnector inside type GG1B(F)(Z) switchgear cabinet. 介绍了如何实现GG1B(F)(Z)型高压开关柜整体式真空断路器与隔离开关的机械联锁。
- The test shows that the vacuum circuit breaker with monostable permanent-magnetic operation system could fully reach the operation requirement by the electrified railways. 试验表明,采用单稳态永磁操动系统的真空断路器完全满足电气化铁道的使用要求。
- Main circuit breaker:Imported ABB VD4 vacuum circuit breaker or ZN63(VS1),vacuum circuit breaker made by our company could be equipped with this kind of switchgear. 主配断路器:本开关柜可配用我厂生产的ZN63(VS1)真空断路器,也可配用进口ABB公司生产的VD4真空断路器。
- Main product of corporation:TC-12 outdoor high volt permanent-magnet vacuum automatic circuit recloser、TC-12 outdoor high permanenmagne vacuum circuit breaker. 公司主导产品有:TC-12户外高压永磁真空自动重合器、TC-12户外高压永磁真空断路器。
- Ma Shaohua, Wang Jimei.Research and design of permanet magnetic actuator for 72.5kV HV vacuum circuit breaker[J].Proceedings of the CSEE, 2001, 21(12): 109-114. [1]马少华;王季梅.;72
- The phenomena of delay discharge in vacuum circuit breaker(VCB)are related to their reliability and over-voltage.The mechanism and the treating methods are proposed in this paper. 真空断路弧后延时重击穿现象可能引起危险的过电压,破坏断路器的稳定运行。文中研究探讨了产生此现象的机理和应采取的对策。
- The equipment uses vacuum circuit breaker as executing components and use parallel capacitor banks as compensating components.It can check in or out capacitor banks cyclically. 该装置以真空断路器作为执行元件、以并联电容器作为补偿元件,实现“循环投切”。
- ZN63 M1-12 indoor high voltage vacuum circuit breaker operated by permanence magnetic mechanism. intelligent control, simple operating program, less maintenance, install size is compatible with VS1, VD4. 是由新一代高可靠、维护的永磁机构操动,智能化控制,操作程序简单,外型安装尺寸与VS1、D4完全兼容。
- ZN63M1-12 indoor high voltage vacuum circuit breaker operated by permanence magnetic mechanism. intelligent control, simple operating program, less maintenance, install size is compatible with VS1, VD4. 是由新一代高可靠、免维护的永磁机构操动,智能化控制,操作程序简单,外型安装尺寸与VS1、VD4完全兼容。
- The principle, action and control process of permanent magnet driven machinery were introduced, its characteristic was analyzed, and its application to medium pressure vacuum circuit breaker was expounded. 摘要介绍了永磁操动机构的原理、动作和控制过程,分析了永磁操动机构的特性,阐述了其在中压真空断路器上的应用。
- Abstract:Vacuity tester has the features of easy to use, simple to install, and reliable to measure the vacuity of arcextinguishing chamber of a highvoltage vacuum circuit breaker. 摘要:真空度测试仪在测试高压真空断路器真空灭弧室真空度时具有操作及安装简便、测试结果可信等优点。
- The data acquisition card is applied in the vacuum circuit breaker's mechanical characteristics detector to achieve the acquisition of analog, switch state and timing counting functions. 该采集卡应用于真空断路器机械特性检测仪中,实现采集模拟量,开关量以及定时计数等主要功能。
- V2000 vacuum circuit breaker was 12KV degree indoor HV switchgear. Apply to fixed cupboard, handcart cupboard, medium cupboard and so. Except general advantage also have more advance function. V2000型真空断路器为12千伏电压等级户内高压开关设备。适用于固定柜、手推柜、中置柜等所有开关应用场所。它除具备一般真空断路器优点外,还具备有更多先进功能。
- In a10kV distribution system,when shunt ca-pacitors are switched off by vacuum circuit breakers,restrike overvoltage often occurs. 电力系统中使用真空断路器切除无功补偿用并联电容器时,容易产生重燃过电压,严重影响并联电容的安全运行。