您要查找的是不是:
- new flow injection analysis 新的流动注射分析
- The dispersion of flow injection analysis system is an improtant parameter. 在流动注射分析中,分散度是一个很重要的参数。
- Flow injection analysis (FIA), developed in 1975 by Ruzika and Hansen of the Technical University of Denmark, is a new analytical technique for sample solutions being effectively dealt with and determined in non-equilibrium state. 流动注射分析(Flow Injection Analysis,FIA)是1975年丹麦技术大学Ruzicka和Hansen提出的一种在非平衡状态下对待测样品溶液进行高效处理、测定的新方法,它从根本上改变了几百年来分析化学测定必须在物理化学平衡状态下完成的传统,开辟了溶液分析化学的一个全新领域。
- A novel on-line Redox flow injection analysis method for the determination of doxium has been established. 建立了在线氧化还原流动注射分光光度法测定多贝斯的新方法。
- A system of Ce(SO4)2H2SO4 for determination of COD in natural water samples by reversed flow injection analysis is discussed. 研究了Ce(SO4)2?H2SO4体系反向流动注射分析法测定环境水中化学需氧量(COD)的试验条件。
- A new flow injection chemiluminescence method for the determination of sparfloxacin is described. It is found that the chemiluminescence reaction of Luminol-H2O2 can be sensitized by sparfloxacin. 基于在碱性介质中;司帕沙星对Luminol-H2O2化学发光体系有较强的增敏作用;建立了司帕沙星的流动注射化学发光分析法.
- This paper presents a test method of sodium carbonate from produced water in ASP drive oilfield using flow injection analysis(FIA). 该文提出了用流动注射法(FIA)测定ASP驱油田产出水中的碳酸钠浓度的方法。
- A new flow injection system, air-segmented FIA was proposed for rapid and sensitive determination of trace vanadium in tap and natural river waters based on its catalysis of oxidation of gallic acid by bromate. 应用空气整段间隔流动注射法与改进的钒-溴酸钾-没食子酸催化动力学反应体系相结合,建立了测定天然水体中痕量钒的催化动力学光度FIA法。 通过使用一个自制的进样阀,使样品带在反应管道中的留存时间得到延长,加热允许温度得到提高。
- A flow Injection analysis (FIA) with copper(I)-2, 9-dimethyl-1, 10-phenanthroline has been established using non-ionic surfactant Triton X-100 as solubilizer. 本文用非离子表面活性剂Triton X-100增溶新亚铜试剂,建立了直接水相流动注射分析测定微量铜的快速简便方法。
- A method of flow injection analysis (FIA) was introduced into the spectrophotometric system of Mo-SCN~--RhB ternary complex for the determination of trace Mo. 本文将流动注射分析(FIA)引入Mo-SCN~--RhB三元缔合体系测定痕量Mo。
- In the course of electroless nickel plating,flow injection analysis(FIA)spectrophotometry was established for real-time on-line analysis of nickel in the bath. 在化学镀镍过程中 ,建立了流动注射光度法在线实时监测化学镀镍浴中镍浓度随时间变化的方法。
- Flow injection analysis combined with inductively coupled plasma atomic emission spectrometry was adopted for determination of calcium and magnesium in natural water. 本文采用流动注射-电感耦合等离子体发射光谱联用技术测定了天然水中的钙、镁元素。
- An AChE biosensor,connected with a flow injection analysis system(FIA),was derigned to detect methyl-parathion in seawater rapidly,by colorimetric determination of the activity change of the immobilized AChE from the organophosphorus pesticide. 将乙酰胆碱酯酶(acetylcholinesterase,AChE)传感器与流动注射系统(flow injection analysis system,FIA)相结合,通过光学方法测定固定化酶受农药抑制后的残余活性,对海水中微量甲基对硫磷进行定量分析。
- reversed flow injection analysis( r- FIA) 反相流动注射
- Reverse phase flow injection analysis 反相流动注射
- Reversed flow injection analysis 反相流动注射分析
- Reversed-phase flow injection analysis 反相流动注射分析法
- Continuous flow injection analysis method 连续流动分析法
- Flow injection analysis instrument 流动注射分析仪
- A New Flow Injection Calibration System Based on Automatic Diagnosis and Correction for Fault Peak Signal Using Flow Injection Gradient Information 一种基于流动注射梯度技术识别异常峰及校正的方法