您要查找的是不是:
- Other factors, such as age, total irradiation dose, daily fraction, chemotherapy, did not show significant correlations with the results of vitreous fluorophotometry in our series. 其他的因素如年龄,总辐射剂量,每日辐射分量,化学治疗的有无等,在本篇所收集的6例中,与玻璃体萤光光度计检查结果并与明显相关。
- Total Irradiation Dose (TID) 总剂量
- total irradiation dose 总剂量辐照
- Additional absorption increased with irradiation dose increasing. 随着辐照剂量的增加,色心附加吸收峰增强。
- In the case of given degree of degradation, the dose rate will varied oppositelywith irradiation dose. 当裂解度一定时,剂量率与剂量成反变关系。
- There is dose-effect relationship between irradiation dose and the enabling of P65 signal conduct access of adenoid cystic carcinoma cells . 放射剂量与腺样囊性癌P65信号传导通路开放存在量效关系,在一定范围内,随着放射剂量增加,P65信号通路的表达更为明显。
- The principle of EPR dosimetry is based on the fact that the concentration of radiation-induced radicals increases with irradiation dose. 目前,将EPR方法用于低剂量测定还存在一些困难,为了降低测量阈值,减小误差,优化方法,需要进一步研究该方法的影响因素。
- Radiation damage in W has been studied as a function of irradiation dose by heavy ion simulation and positron annihilation lifetime measurement. 采用重离子辐照模拟方法和正电子湮没寿命测量技术研究了钨辐射损伤随辐照剂量的变化。
- There was mass loss of the silicone rubber after VUV irradiation and the mass loss percentage increased with the increase of irradiation dose. 真空紫外辐照后,硅橡胶的质量有所损失,其质损率随辐照剂量的增加而增加;
- Effects of the grafting conditions, such as type of diluents, irradiation dose, dose rate and monomer concentration, were investigated. 研究了溶剂种类、单体浓度、辐射剂量以及剂量率等因素对接枝反应的影响。
- At low irradiation dose, the concentration of active platinum increases and the performance of the device optimized as the dose of proton irradiation increases. 结果表明,当辐照剂量较低时,随着辐照剂量的增加,电活性铂浓度不断提高,器件性能不断优化。
- The decontamination irradiation dose is not affected by changes of initial bacteria load under normal and steady production condition, and had 99.73% confidence limits. 应用该方法提供的辐照灭菌剂量不受初始污染正常波动的影响,在产品稳定生产期间内持续有效且有99.;73%25的置信区间,可有效提高辐照产品的合格率。
- Relationship between daily diffuse irradiation and daily total irradiation is analyzed, based on data form Beijing and Chengdu. Polynomial models for Beijing and Chengdu are established to estimate K d form K t . 文章根据北京和成都两地的实测数据 ,分析了日散射与日总射的关系 ,分别建立了两地散射系数Kd 与总辐射系数Kt 的多项式拟合模型。
- And the modified membranes with different grafting ratio are obtained by changing the conditions,such as solvent,irradiation dose,and irradiation dose rate. 通过改变溶剂、辐照剂量、辐照剂量率等条件,获得了具有不同接枝率的改性聚醚砜膜,提高接枝率有助于改善聚醚砜膜的亲水性。
- The apparent D10 value was used as D10, upper control line of (average)X control map is used as N0, the irradiation dose was calculated by formula D=D10lg (N0/N). 具体为细菌表观D10值作为D10值,以初始污染的(平均值)X控制图的上控制线为N0,采用公式法计算中药的消毒剂量。
- LLL has the biomodulatory effect on skeletal muscle cells, which are determined by not only the irradiation dose and wavelength of laser but also the physiological state of the cells. 低强度激光对骨骼肌细胞具有双向生物调节作用,这种调节作用既与激光的照射剂量及波长有关,也与细胞的生理状态有关。
- In this work the radiation effects of CPE/LDPE blends with dif-ferent composition were studied. The obtained results prove the suitability of equa-tion describing the relation between irradiation dose and sol fraction given in re-ference. 研究了氯化聚乙烯(CPE)/低密度聚乙烯(LDPE)共混体系的辐射交联规律,证实该共混体系对文献[8]所给的溶胶分数与辐射剂量关系的适应性。
- One body-two tubes"applicator can not only increase the intratarget dosage to improve the local control of tumor recurrence,but also it can reduce irradiation dose to the normal tissues. 结论:新型鼻咽癌施源器的设计应用及临床效果,在提高靶区剂量改善局部控制的同时降低了正常组织放射剂量,值得进一步临床推广应用。
- The mass rally was a total fiasco. 那次群众集会彻底失败。
- Methods Parking Ir 192 in centrum for irradiating while measuring irradiation dose by thermoluminescent dosimeter, which laid in the position equivalent to spinal cord. 方法将铱192放射源置于椎体中照射,在椎体后椎管前缘相当于脊髓部位放置热释光计量计测量照射量。